FOAM
EXTINGUISHING EQUIPMENT
FOAM EMULSION
FireDos FOAM PROPORTIONING SYSTEMS
FireDos is an automatic foaming system that dispenses foam exactly according to the water flow rate and, unlike foam mixers, line foam dispensers and re-pump systems, does not depend on multiple variables below the flow and amount of equipment running. The foam system has a water motor that uses the energy of the water flow and has an extremely low pressure drop: up to a maximum flow of 1.8 bar.
FireDos foam systems have a water flow rate of 40 l / min to 20,000 l / min. By connecting the systems together, larger flows can also be passed.
The dosing percentage is 0.1% to 6% - according to the customer's wishes.
FireDos systems are manufactured:
-
in the portable version
-
in the local version
-
in the mobile version
-
in the easily disassembled version




FOAM PROPORTIONING SYSTEM Bladder Tank
Standard technical data:
Material: SA 516 Gr. 70
Hatch: DN450
Mixer input: ANSI 150 RF flange
Faucet outlet: ANSI 150 RF flange
Mixer material: SA 106 Gr. B - SA 105
Membrane material: Hypalon neoprene
Water and foam nozzle material: SS
Visible level indicator
Flow direction: from left to right
Design pressure: 12 bar
Test pressure: 18 bar
Painted: RAL3000
Color thickness: 80-120 μ
Installation options: horizontal, vertical, double tank
Foam location: inside the membrane
Volume: 600 - 10000 L (other volumes on request)
Mixing percentage: 3%, 6% (optional)
Additional options - special painting
-
housing material AISI 316
-
second design pressure
-
second flow direction
-
the second type of flange

FAST FOAM MIXING SYSTEM
KSS - 200/1000
Intended for rapid and radical intervention in common A and B fires. It fires large flames in seconds and is especially important in small personnel commandos.
The device emits a very powerful stream of foam. The foam sticks to the walls and ceilings and the flames are extinguished in seconds. Uses Class A and B foam with 0.5%. Productivity: 200 l / min and 500 l / min. It is also available at 1000 l / min. One spoonful of foam is consumed with one tank full of water. Input: KSS-200 - 2 inches; KSS-500 - 2.5 or 3 inches. It is easy to use by a man in the country who comes alone on fire.


PORTABLE FOAM DEVICE
Uprim
Working principle: the water reaches the Uprim frother 1 inch
through the pressure hose. The water flow in the foam dispenser absorbs the foam a mixture of water and foam enters the cylinder and the nozzle.
In the foam nozzle water and the foaming solvent mixes with air; and
is formed by foam.
Fire extinguishing capacity of more than 40 foam extinguishers
Ultra light balloon made of polyethylene
Visually visible foam level
Large handle, comfortable to work with fire gloves
The balloon is easy to open for quick refilling
Includes low-level foam hose - for remote extinguishing, and medium-fold foam generator - for volumetric extinguishing.
Where is the Uprim foam extinguisher used?
heating terminals
in fire cabinets - to increase fire extinguishing efficiency
fire works
in the rescue service: car in case of fire, above the traffic accident, after-fire-fighting work, liquid heating in case of fire - in the final stage of fire-fighting
to cover the average fold of smaller foci with foam
at various industrial sites
Technical specifications:
foam cylinder capacity 10 L
maximum resistance to the corrosive effects of foams and weather
flow rate according to water-foam solvent - 60 l / min
possible foaming dose: 6%, 3% or 1%
high speed foam nozzles
simple and easy maintenance
large opening for filling the cylinder
operating pressure: 3 - 10 bar
range of foam flow: low multiplicity - up to 9 m, average multiplicity - up to 6 m.
foaming: low - up to 10, medium - up to 70.
work with one filler: 6% - 4 min, 3% - 8 min, 1% - 24 min.
with one foam cylinder it is possible to obtain a medium multiplicity
finished foam: 6% - 8.5 m³, 3% - 17 m³, 1% - 50 m³.
incoming water hose: according to the customer's request - either 1-inch or 1.5-inch.

Foam generator for fire extinguishing
Standard technical data
Material: AISI 304
Connection: 2 “ANSI 150 RF flange
Flange material: ASTM A 105
Painted: RAL3000
Color thickness: 80-120 μ
Additional options - special painting:
AISI 316
flange SS
the second type of flange
Model:
MEF-1
MEF-2
MEF-3
MEF-4
MEF-5
MEF-6
MEF-7
MEF-8
MEF-10
Productivity:
116 l / min @ 5 bar
208 l / min @ 5 bar
324 l / min @ 5 bar
429 l / min @ 5 bar
507 l / min @ 5 bar
636 l / min @ 5 bar
730 l / min @ 5 bar
831 l / min @ 5 bar
1000 l / min @ 7 bar

FOAM MIXER Protek Style # 205
Works well with 5 bar and 7 bar water pipes
Flow rate 775 l / min, 950 l / min or 1325 l / min
Ideally compatible with the Protek Style # 324 automatic sprayer with a capacity ranging from 190 to 1325 l / min
Equipped with non-return valve
Equipped with a 1.2 m suction hose and a 38 cm stainless suction hose
Works with virtually all foams
2.5-inch rotary input and 2.5-inch output
Foam concentration regulator: .....%
Material - light alloy
Length - 305 mm
Weight - 3.6 kg
Complete with # 324 automatic sprayer, it is a real A-Class and B-Class Fire Extinguisher!
FOAM EMULSION
FIRETEK offers a wide range of both synthetic and protein-based products
high quality Dafo Fomtec AB fire foams.
Videos of the offered products can be watched on the Fomtec Youtube channel:
FOAM AFFF
The water-forming foam is intended for extinguishing Class B hydrocarbon fires, such as oil, diesel, gasoline, aviation heating. This foam can be used with both foam and water jets. The foaming agent that forms the water film is particularly well suited for the rapid killing of flames: the thin water film formed at the molecular level travels along the burning surface in front of the foam layer and dampens the flames even before the foam layer arrives. The foam can be used with all available extinguishing powders and can be used in dual extinguishing foam / powder systems. The water-forming foam is available in concentrations of 6%, 3%, 1% and 0.5%. There are also several different versions for frost resistance and different approved foams: UL, FM, Lloyd, EN 1568, Bureau Veritas, ICAO - according to customer requirements.
The AFFF foam selection can be found here :
FOAM AFFF ARC
The alcohol-resistant water-forming foam is intended for extinguishing Class B hydrocarbon fires, such as oil, diesel, gasoline, aviation heating, as well as polar solvent decomposing foam fires, such as methanol, isopropanol, gasoline additive MTBE, and others. This foam can be used with both foam and water jets. The fine water film formed at the molecular level in oil, diesel and gasoline fires travels along the burning surface in front of the foam layer and dampens the flames even before the foam layer arrives. In alcohol fires, the foam forms a thick polymer layer that protects the foam layer from aggressive liquids. The foam can be used with all available fire extinguishing powders. The alcohol-resistant water-forming foam is available in concentrations of 3x6% (3% for gasoline fires; 6% for alcohol fires), 3x3%, 1x3%, and 1x1%, in a conventional embodiment, and in a particularly fluid (Newtonian) embodiment. There are also several different versions for frost resistance and different approved foams: UL, FM, Lloyd, EN 1568, Bureau Veritas, RINA, DNV - according to customer requirements. A Miljö version is available - especially environmentally friendly.
The AFFF ARC selection is available here :
http://www.fomtec.com/aqueous-film-forming-foam-alcohol-resistant-concentrate/category36.html
FOAM Synthetic Multi Purpose
It is a universal foam that forms low, medium and high order foams.
There are two types of LS and MB:
LS is a foaming agent that can extinguish Class B hydrocarbon fires (oil, diesel, gasoline, aviation fuel, polar substances such as acetone, isopropyl alcohol, etc.), such as spilled heating minor cuts (low and medium frequency), hazardous basements and engine rooms (medium and high frequency), fires of cryogenic combustible liquids; evaporation of toxic liquids can also be prevented. Medium multiplicity is better suited for extinguishing smaller spaces, such as basements in buildings; however, the high frequency of the equipment for flooding the cargo and engine rooms. This foam is especially good for use in poorly accessible rooms and where fire damage must be minimized.
MB is a universal foaming agent that forms low, medium and high-frequency foams that can extinguish Class B hydrocarbon fires, such as spilled heating small sections (low and medium multiplicity), hazardous basements and marine engine rooms (medium and high multiplicity), cryogenic combustible liquids. ; evaporation of toxic liquids can also be prevented. Medium and high frequency HiEx foam can be used for total immersion of Class A and B fires. Medium multiplicity is better suited for extinguishing smaller spaces, such as basements in buildings; however, the high frequency of the equipment for flooding the cargo and engine rooms. This foam is especially good for use in poorly accessible rooms and where fire damage must be minimized.
The selection of synthetic foams can be found here :
http://www.fomtec.com/synthetic-multi-purpose/category37.html
FOAM Fluorine free
Do not form in water film in gasoline fires (although the resulting foam layer also effectively extinguishes gasoline), but forms a thick polymer membrane in polar liquid fires. This is a cheaper solution for objects where it is known in advance that these are only polar combustible liquids: alcohols, solvents, etc.
The selection of fluorine free foam can be found here :
FOAM Foam Solutions
Ready-to-use alcohol-resistant mixture of water and foam. A reliable fire-fighting design is achievable for all types of fires.
In polar liquid fires, Alpha forms a thick polymer membrane that protects the foam layer from decomposition.
In fires of non-polar heating, it forms a fine film of water that moves in front of the foam layer and dampens the flames before the foam layer reaches (AFFF effect).
Alpha R is designed to have a much longer lifespan than conventional water and AFFF blends.
This solution is also alcohol-resistant and stable on storage, unlike conventional ARC solutions.
Ideal for use in stand-alone CAFS systems.
The Foam solution selection can be found here :
FOAM Class
Specially selected mixture of surfactants, solvents and stabilizers for high activity hydrocarbons for use in Class A fires. Forrex Ultra does not contain any hazardous substances and does not require special transport labels. Forrex Ultra provides excellent Class A fire fighting, ensuring deep penetration of water into combustible materials. At low concentrations, the foam can be used simply as a wetting agent. Forrex Ultra is well suited for use with foam pipes and generators as well as conventional water jets. The foam is compatible with all available extinguishing powders.
The selection of Class A foam can be found here :
FOAM FFFP
The water film-forming fluoroprotein foam contains hydrolyzed protein, preservatives and fluorinated surfactants for maximum synergistic fire-fighting effect. The mixture of fluorochemicals selected is effective in reducing the surface tension of the water as well as lowering the tension between the water and oil sufficiently to form a stable aqueous film on the surface of the combustible liquid. As a result, higher fire extinguishing properties are achieved than with synthetic foams. The addition of protein to the composition provides a dense foam layer with excellent re-ignition resistance. The foam is available in concentrations of 3% or 6% and with approvals and compliances such as ICAO, EN 1568.
The selection of FFFP foam can be found here :
FOAM FFFP ARC
FFFP ARC is a universal foam that can be used as an effective water-film-forming fluoroprotein foam in hydrocarbon fires and as an alcohol-resistant foam in polar solvent fires to form a thick polymer membrane on the surface of the combustible liquid. FFFP ARC ensures a reliable performance even for the combustion of the harshest liquids. Its excellent fire-fighting design for all types of combustible liquids, whether low or medium foam, ensures maximum safety in both mobile fire and local fire protection. FFFP ARC is available in concentrations of 3x3% and 3x6% (3% for hydrocarbons and 6% for polar solvents). A 3x3% concentration foam is available in the Avalanche NV version, which is a highly effective liquid based on an environmentally friendly protein and does not contain the thickening polymers of the usual alcohol-resistant foam. Its high flowability makes dosing foam easier and more accurate for both portable and stationary dispensers, even at the lowest temperatures (-18ºC). Avalanche NV has the advantage of dosing at 3% for all Class B fires, including polar solvents when using fresh or sea water. Avalanche NV complies with the EN 1568 standard.
The selection of FFFP ARC foam can be found here :
FOAM for Training
Gently and gently formulated Universal Synthetic Foam, designed for foam extinguishing training without the use of its main extinguishing foams. The foam is readily biodegradable and is ideal for training in rescue schools and industrial sites.
The training foam selection can be found here :