top of page
AEROSOL
Cylindrical
generators
FP-20
Model
FP-20T
Activation method
Thermal
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.6 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
310 g
FPC elements mass
20 g
Operational emptying time
5 - 10 seconds
Outlet
1
Issue length
1 m
Dimensions
Q: 170 mm (with plug housing) Ø 32 mm
Self-activation temperature
300 ºC
Fire class
EN2: A, B, C, F / NFPA 10: A, B, C
FP-40
Model
FP-40T
Activation method
Thermal
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.6 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
610 g
FPC elements mass
40 g
Operational emptying time
5 - 10 seconds
Outlet
1
Issue length
1 m
Dimensions
Q: 145 mm (with plug housing) Ø 51 mm
Self-activation temperature
300 ºC
Fire class
EN2: A, B, C, F / NFPA 10: A, B, C
FP-80
Model
FP-80T
Activation method
Thermal
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.6 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
870 g
FPC elements mass
80 g
Operational emptying time
5 - 10 seconds
Outlet
1
Issue length
2 m
Dimensions
Q: 185 mm (with plug housing) Ø 51 mm
Self-activation temperature
300 ºC
Fire class
EN2: A, B, C, F / NFPA 10: A, B, C
FP-100S
Model
FP-100S
Activation method
Thermal
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.6 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
1370
FPC elemendi mass
100 g
Operational emptying time
5 - 10 seconds
Outlet
1
Issue length
1 m
Dimensions
H: 155 mm (with plug housing) Ø 84 mm
Self-activation temperature
300 ºC
Fire class
EN2: A, B, C, F / NFPA 10: A, B, C
FP-200S
Model
FP-200S
Activation method
Thermal
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.6 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
1840
FPC elemendi mass
200 g
Operational emptying time
5 - 10 seconds
Outlet
1
Issue length
2 m
Dimensions
H: 185 mm (with plug housing) Ø 84 mm
Self-activation temperature
300 ºC
Fire class
EN2: A, B, C, F / NFPA 10: A, B, C
FP-500S
Model
FP-500S
Activation method
Thermal
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.6 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
3340 g
FPC elemendi mass
500 g
Operational emptying time
5 - 10 seconds
Outlet
1
Issue length
3 m
Dimensions
Q: 295 mm (with plug housing) Ø 84 mm
Self-activation temperature
300 ºC
Fire class
EN2: A, B, C, F / NFPA 10: A, B, C
Unpressurized
15-year product life
Non-oxygen depleting
HFC-free
CFC-free
Global warming potential zero
Halon alternative
Zero ozone depletion potential
Manufactured according to ISO 14001/9001 standards
bottom of page