top of page
FirePro logo red.png

AEROSOL

ATEX
generators

firepro-footer-certificates.png
FP-100_EX.png

FP-100S

Model
FP-100S
Activation method
Thermal
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.6 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
1370
FPC elements  mass
100 g
Operational emptying time
5 - 10 seconds
Dimensions
H: 155 mm (with plug housing) Ø 84 mm
Fire class
EN2: A, B, C, F / NFPA 10: A, B, C
ex-zone.png
atex-generators.png

The ATEX product line has been successfully tested for use in Explosive Atmospheres. The ATEX generators are designed to suppress fires in explosive atmosphere of gas or dust mixtures.

FP-200_EX.png

FP-200S

Model
FP-200S
Activation method
Thermal
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.6 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
1840
FPC elements  mass
200 g
Operational emptying time
5 - 10 seconds
Dimensions
H: 185 mm (with plug housing) Ø 84 mm
Fire class
EN2: A, B, C, F / NFPA 10: A, B, C
oil-plant.png
FP-500_EX.png

FP-500S

Model
FP-500S
Activation method
Thermal
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.6 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
3340 g
FPC elements  mass
500 g
Operational emptying time
5 - 10 seconds
Dimensions
H: 295 mm (with plug housing)  Ø 84 mm
Fire class
EN2: A, B, C, F / NFPA 10: A, B, C
industrial-plant.png

FP-500S

FP-1200_EX.png
Model
FP-1200 EX
Activation method
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.8 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
17050
FPC elemendi mass
1200 g
Operational emptying time
10 - 15 seconds
Dimensions
365mm x 450mm x 310mm
Fire class
 A, B, C, F
oil-gas-platform.png

FP-500S

FP-1200_EX.png
Model
FP-2000 EX
Activation method
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.8 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
21650 g
FPC elemendi mass
2000
Operational emptying time
10 - 15 seconds
Dimensions
365mm x 450mm x 310mm
Fire class
 A, B, C, F
piping-industrial.png

FP-500S

FP-1200_EX.png
Model
FP-3000 EX
Activation method
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.8 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
22450 g
FPC elemendi mass
3000 g
Operational emptying time
15 - 20 seconds
Dimensions
365mm x 450mm x 310mm
Fire class
 A, B, C, F
silo-storage.png

FP-500S

FP-1200_EX.png
Model
FP-4200 EX
Activation method
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.8 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
30910 g
FPC elemendi mass
4200 g
Operational emptying time
10 - 20 seconds
Dimensions
365mm x 450mm x 310mm
Fire class
 A, B, C, F
tunnel-mine.png

FP-500S

FP-1200_EX.png
Model
FP-5700 EX
Activation method
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.8 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
33710 g
FPC elemendi mass
5700 g
Operational emptying time
10 - 20 seconds
Dimensions
365mm x 450mm x 310mm
Fire class
 A, B, C, F
power-plant.png

FP-500S

FP-100T_(2G-EX).png
Model
FP-100T (2G-EX)
Activation method
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.8 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
1500 g
FPC elemendi mass
100 g
Operational emptying time
5 - 10 seconds
Dimensions
84 mm: 155 mm
Fire class
 A, B, C, F
atm-fire-suppression.png

FP-500S

FP-200T_(2G-EX).png
Model
FP-200T (2G-EX)
Activation method
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.8 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
1945
FPC elemendi mass
200 g
Operational emptying time
5 - 10 seconds
Dimensions
84 mm: 185 mm
Fire class
 A, B, C, F
atm-internal.png
FP-500T_(2G-EX).png

FP-500S

Model
FP-500T (2G-EX)
Activation method
Electrical (Minimum pulse voltage: 1.5 VDC, minimum pulse current: 0.8 A, minimum pulse duration: 0.5 s)
Test current
Maximum 5 mA
Gross weight
3415
FPC elemendi mass
500 g
Operational emptying time
5 - 10 seconds
Dimensions
84 mm: 295 mm
Fire class
 A, B, C, F
non-pressurized-fire-suppression.png

Unpressurized

15years.jpg

15-year product life

environmentally-friendly-fire-protection

Non-oxygen depleting

hfc-free-technology.png

HFC-free

cfc-free-fire-protection.png

CFC-free

environmentally-friendly-fire-suppression

Global warming potential zero

epa-snap-certified.png

Halon alternative

ozone-friendly-fire-suppression-systems.

Zero ozone depletion potential

iso-certified-fire-suppression-system.pn

Manufactured according to ISO 14001/9001 standards

FIRETEK offers an Aerosol based on the customer's wishes extinguishing systems project.   

The design stages are the preliminary project, the main project and the working project.

 

FIRETEK OFFERS AEROSOL  EXTINGUISHING SYSTEMS  CONSTRUCTION AND MAINTENANCE

bottom of page